IVF centre in Goa
Consultations in Panjim · Margao · Mapusa · Vasco
Call
Page 12 of 72Embryologist path · Lab Textbook
Part 1: Andrology, semen preparation and IUI · Day 2
Page 12 of 72

Microfluidic sperm sorting

On this page you will learn

The idea

Swim-up and density gradients have been used for decades. Both have drawbacks: swim-up recovers few sperm from poor samples, and centrifugation can expose sperm to reactive oxygen species from leucocytes and damaged cells. Microfluidic sperm sorting tries to select good sperm more gently.

A microfluidic device is a small chip or chamber with very narrow channels or a membrane full of tiny pores. Semen is loaded into an inlet chamber, and culture medium is placed in an outlet chamber above or beside it.

Only sperm that can swim actively and progressively through the channels or pores reach the medium. Immotile sperm, cells and debris stay behind. There is no centrifugation, and the method imitates, in a simple way, the narrow paths that sperm travel in the female tract.

Possible advantages

Real limits

Present microfluidic sorting honestly: as a useful tool for some samples and some situations, not as a routine improvement for every couple. The choice of method is part of the laboratory protocol and the clinical plan (page 13).

At the bench

Each device has its own instructions for use, which you must follow exactly. The general sequence is:

Label device and tube, witnessLoad semen into the inletAdd medium to the outletIncubate level, undisturbedCollect from the outletAssess and record
Microfluidic sorting, step by step.
  1. Check identity, label the device and the collection tube on their bodies with two identifiers, and witness (page 3).
  2. Bring the device and the medium to the specified temperature.
  3. Assess the liquefied semen (pages 6-7). Very viscous samples may not load well; follow your protocol for viscosity.
  4. Load the specified volume of semen into the inlet, slowly and without bubbles.
  5. Add the specified volume of medium to the outlet chamber, again without bubbles.
  6. Incubate at the stated temperature for the stated time, often around 30 minutes, keeping the device level and undisturbed.
  7. Collect the medium from the outlet with a fresh sterile pipette, taking care not to draw from the inlet.
  8. Assess the sorted sample: volume, concentration, motility and total motile count (page 14), and record everything.

Other sperm selection methods

You will hear about several other methods. Each is used for specific situations, and none has replaced standard preparation:

For each of these, laboratory differences are easier to show than clinical benefit. Learn what each does, and treat claims with the same caution as for microfluidics.

Common errors

Key points

Check yourself

  1. How does a microfluidic device separate motile sperm from the rest?

    Semen is loaded into an inlet and medium into an outlet chamber. Only sperm that can swim actively and progressively through the channels or pores reach the medium. Immotile sperm, cells and debris stay behind.

  2. Give two advantages and two limits of microfluidic sorting.

    Advantages: no centrifugation, so less mechanical stress and less contact with leucocytes; and a highly motile fraction with normal-looking morphology. Limits: a lower yield than a density gradient; and it depends on motility.

  3. Why does lower DNA fragmentation not automatically mean better clinical results?

    A laboratory measure is not the same as a clinical result. Studies comparing pregnancy and live birth outcomes have given mixed results, and the evidence is still developing.

  4. For which kind of sample is microfluidic sorting unsuitable?

    A sample with very few motile sperm, or surgically retrieved sperm with poor movement.

  5. From page 11: In a density gradient, where do leucocytes and debris end up, and why?

    They are less dense than mature sperm, so they stay at the interfaces between the layers (page 11).

  6. From page 08: Why should the proportion of live sperm never be lower than the proportion of motile sperm?

    Because a moving sperm is alive. If live is lower than motile, one of the two tests is wrong (page 8).

Contents and reading plan

Questions on this page

Does microfluidic sorting improve pregnancy chances?

It can select sperm with good motility and often lower DNA fragmentation, but studies of clinical outcomes have given mixed results. It is a tool for some samples, not a routine improvement for all.

Can microfluidics be used for testicular sperm?

Usually not, because the method depends on sperm swimming actively through channels or pores. Surgically retrieved sperm often have poor movement (see page 54).

Do I need a witness when I use a sorting device?

Yes. The device and the collection tube are labelled with two identifiers and the sample transfer is witnessed, exactly as for swim-up or a density gradient (page 3).

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Training Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.