Searching follicular fluid

On this page you will learn

Finding the oocytes

The follicular fluid that arrives from pick-up (page 22) contains the oocytes, each wrapped in its cloud of cumulus cells. Your job is to find every one, quickly, and move it into a protected medium without cooling it, exposing it to strong light, or losing track of whose it is. It is the first moment the oocyte is in your hands, and it sets the tone for everything that follows.

What you are looking for

Under the stereo microscope, a cumulus-oocyte complex (COC) looks like a glistening, translucent cloud of cells, sometimes large and fluffy, sometimes compact. In the centre you may see the oocyte as a small dark spot surrounded by a tighter layer of cells, the corona radiata. Page 24 describes the COC in detail. Granulosa cell clumps can look similar but lack the oocyte. Blood clots are red and dense. With practice you will recognise a COC almost at a glance.

Setting up

At the bench: searching a tube

1. Confirm the tube's patient2. Pour a thin layer3. Scan in rows, dim light4. COC into the wash dish5. Count aloud and record6. Rinse; to holding dish7. Recheck tube and dish
Figure: searching follicular fluid, tube by tube.
  1. Receive the tube from the hatch. Confirm it is for the patient being treated now.
  2. Pour the fluid in a thin layer into a warmed search dish. A thin layer is easier to scan.
  3. Scan systematically, for example in rows from one edge to the other, so no area is missed. Use low magnification and a dim light.
  4. When you find a COC, pick it up with as little fluid as possible and move it into the wash dish.
  5. Count each one aloud and record it. Tell the clinician the running total.
  6. Rinse COCs briefly in fresh handling medium to remove blood and debris, then transfer them to the holding dish and return it to the incubator.
  7. Check the bottom of the tube and look again at the dish before discarding, so nothing is lost.

Work quickly but never carelessly. The fluid cools and changes pH as it sits in room air. Most laboratories aim to search each tube within a short time of receiving it, and to keep the oocytes in a buffered medium at body temperature at every step.

Blood-stained or clotted fluid

Blood and clots can hide COCs. Spread the fluid more thinly, examine clots carefully, and gently tease a clot apart with a needle or pipette if a COC may be trapped. Rinse well, because blood is harmful to the oocyte.

When no oocytes are found

Tell the clinician at once, while the procedure is still under way. Keep all fluid until the clinician and the senior embryologist agree it can be discarded, and re-search it if asked. This is a hard moment for the couple and the team: report facts calmly and clearly.

Witnessing

Only one patient's fluid is on the search station at a time. Search dishes from the previous patient are cleared before the next case begins. The transfer of COCs into the labelled holding dish is witnessed and recorded under your laboratory's system (page 55).

Common errors

Key points

Check yourself

  1. Describe how a COC looks under the stereo microscope, and how it differs from a granulosa clump.

    A glistening, translucent cloud of cells, large and fluffy or compact, with the oocyte as a small dark spot in the centre inside the corona radiata. A granulosa clump can look similar but has no oocyte.

  2. Why should the fluid be poured in a thin layer?

    A thin layer is easier to scan, so no COC is missed.

  3. What should you do if no oocytes are found in the first several tubes?

    Tell the clinician at once, while the procedure is still under way. Keep all fluid until the clinician and the senior embryologist agree it can be discarded, and re-search it if asked.

  4. Why must only one patient's material be on the search station at a time?

    So you never lose track of whose oocytes they are. Search dishes from the previous patient are cleared before the next case begins.

  5. From page 22: When is pick-up planned in relation to the trigger?

    Roughly 34 to 36 hours after the trigger, before the follicles would release the oocytes on their own (page 22).

  6. From page 03: Why are perfume and scented products not allowed in the laboratory?

    Their volatile chemicals can harm embryos (page 3).

Contents and reading plan

Questions on this page

Why is a dim light used when searching?

Strong light, especially blue light, can harm oocytes. A dim light and low magnification are enough to see COCs.

When can the follicular fluid be discarded?

Only after the final count is confirmed and the clinician and senior embryologist agree. If in doubt, keep it and search again.

The Genesis ART Textbook is teaching text for trainees and doctors of the Genesis ART Training Academy. It is not treatment advice and not a laboratory standard operating procedure; every technique is learned under supervision. Page numbers never change.